Before installing firesense 2000 linear heat detection cable reference should be made to the zone layout drawings fixing arrangement drawings and the following points should be observed.
Linear heat cable fixings.
Application fixings linear heat detection general guidelines for installation of lhdc.
Linear heat detection fixings and brackets.
Digital lhdc operates at fixed temperatures and is non resettable.
The cable should not be in contact with any material that will act as a heat.
This can be due to either inability to sustain environmental requirements or through prohibitive costs.
Each core is a tinned copper coated spring steel conductor and has special heat reactive polymer insulation.
With a range of up to 10 km and a sampling interval down to 25 cm the system is ideal for fire detection in tunnels and metros as well as large facilities like warehouses and industrial facilities.
Application fixings linear heat detection cable lhdc general guidelines for installation of lhdc.
Fixings should be placed at intervals of no more than 1 2m apart.
In accordance with bs5389 pt1 2002 lhdc should be spaced no more than 5 3m away from any zone boundary or wall and no more than 10 6m between adjacent runs.
The taichung power plant is the largest coal fired power plant in taiwan and the third largest in the world.
Use a suitable clip for whatever you are trying to fix the cable to.
The below drawing represents various clips and fixings that can be used in a typical cable tunnel.
Application fixings linear heat detection cable lhdc general guidelines for installation of lhdc.
The below drawing represents various clips and fixings that can be used in a typical cable tunnel.
Linesense provide the following selection of fixings and clips to retain the linear heat detection lhd cable in place.
The digital linear heat detection cable comprises of a twisted pair two core cable.
Linear heat detection cable.
The correct size and type of cable gland must be used on all junction box etc.
Digital linear heat detection cable.
The analogue linear heat detection cable lhdc is designed to provide detection of fire and overheating in circumstances where other forms of detection would not be viable.
Patol supply a full range as shown over the page.
Lhdc should not be in contact with any material that can act as a heat sink.
Patol supply a full range as shown over the page.
Some 24 000 metres of linear heat detection lhd cable from linesense have been supplied to provide fire protection for one of the world s most important power plants.
Lios de tect is a robust linear heat detection system based on optical fibers.
The correct size and type of cable gland must be used on all junction box etc.